Overload Relay
Overload Relay

Overload Relay

Price 8000 INR/ Piece

MOQ : 1 Piece

Overload Relay Specification

  • Dielectiric Strength
  • 2,500V AC for 1 min
  • Contact Form
  • 1NO+1NC (Normally Open + Normally Closed)
  • Power Consumption
  • Low (static device)
  • Ambient Temperature
  • -5C to +40C
  • Coil Power
  • Not Applicable (Thermal Type)
  • Contact Resistance
  • 100 m
  • Coil Voltage
  • Not Applicable (Thermal Type)
  • Mechanical Life
  • 1,000,000 Operations
  • Working Temperature
  • -5C to +55C
  • Contact Material
  • Silver Alloy
  • Protect Feature
  • Phase Failure Protection, Overcurrent Protection
  • Product Type
  • Thermal Overload Relay
  • Insulation Resistance
  • >100 M at 500V DC
  • Theory
  • Thermal / Electromechanical
  • Usage
  • Motor Protection, Electrical Panels
  • Contact Load
  • 1A, 250V AC (Auxiliary Contact)
  • Operate Time
  • Less Than 2s
  • Terminal Type
  • Screw Terminals
  • Rated Voltage
  • 690V AC
  • Supply Terminal
  • Three Phase
  • Size
  • Standard (specifics on request)
  • Color
  • Black / Silver
  • Dimension (L*W*H)
  • Approx. 65 mm x 45 mm x 78 mm
  • Weight
  • Approx. 250g
  • Mounting Type
  • DIN rail or Screw mounting
  • Standards Compliance
  • IEC 60947-4-1
  • Housing Material
  • High Impact ABS / Polycarbonate
  • Reset Type
  • Manual & Automatic
  • Trip Class
  • Class 10A
  • Current Rating
  • 0.1A to 80A (as per model selection)
  • Storage Temperature
  • -25C to +65C
  • Applicable Motor Power
  • Up to 37kW (depending on relay range)
  • Frequency
  • 50/60 Hz
  • Operating Humidity
  • 95% RH
 

Overload Relay Trade Information

  • Minimum Order Quantity
  • 1 Piece
  • Supply Ability
  • 100 Pieces Per Month
  • Delivery Time
  • 7 Days
 

About Overload Relay



Seize this HOT DEAL on our trending Overload Relay-now on clearance! This splendid, towering device features a transcendent current rating of 0.1A to 80A (model dependent), perfect for protecting motors up to 37kW. Choose between manual and automatic reset and mount with ease, whether DIN rail or screw. Designed for reliability, it meets IEC 60947-4-1, boasts Class 10A tripping, and surpasses industry standards with a high-impact ABS/polycarbonate case. Applicable for electrical panels, it offers robust phase failure and overcurrent protection, ready to perform under demanding industrial conditions.

Extra Features & Industrial Application of Overload Relay

This overload relay delivers phase failure and overcurrent protection with a towering mechanical life of 1,000,000 operations. Its splendid versatility supports both manual and automatic reset, suitable for a broad range of industrial plant applications. The robust ABS or polycarbonate housing stands up to harsh factory environments and consistent high usage. Surface installation is simple-whether on DIN rails or by screw mounting-empowering seamless placement on electrical panels across diverse industrial sites.


Delivery Time, Supply Ability & Certifications

Each order is swiftly handed over after thorough inspection and secure packaging, ensuring your relay arrives pristine and ready to charge into operation. We maintain a strong supply ability across India, backed by a reliable distribution chain. Our product aligns fully with IEC 60947-4-1 certifications, guaranteeing compliance and safety. Whether large-scale plant orders or smaller batches, you can expect dependable delivery schedules tailored to your project timelines.


FAQ's of Overload Relay:


Q: How does the overload relay benefit motor protection in industrial settings?

A: The overload relay offers prompt phase failure and overcurrent protection, safeguarding motors from damaging conditions and significantly extending the lifespan of crucial equipment.

Q: What mounting options are available for this overload relay?

A: The relay accommodates both DIN rail and screw mounting, making it adaptable for various electrical panel configurations and easy integration into new or existing systems.

Q: Where can these overload relays be effectively installed?

A: They are perfect for use in heavy-duty industrial plants and electrical panels, providing robust protection for motors up to 37kW in demanding environments.

Q: What is the typical delivery time after ordering the product?

A: Delivery is handled efficiently, with packaging ensuring product safety. Timelines can vary based on order size and location, but expedited logistics support timely project execution.

Q: What certifications does the overload relay comply with?

A: This relay meets the strict IEC 60947-4-1 standard, ensuring quality and operational safety for industrial users.

Q: What are the key extra features of this overload relay?

A: Key features include manual/automatic reset, high insulation resistance, low power consumption, phase failure protection, and a robust mechanical life for reliable, long-term performance.

Tell us about your requirement
product

Price:

Quantity
Select Unit

  • 50
  • 100
  • 200
  • 250
  • 500
  • 1000+
Additional detail
Mobile number

Email

More Products in Relay Category

Monitoring Relays D2 EFR1

Monitoring Relays D2 EFR1

Price 1850 INR / Piece

Minimum Order Quantity : 10 Pieces

Power Consumption : < 3 VA

Contact Form : 1 Change Over (CO)

Dielectiric Strength : 2500 V AC for 1 min

Theory : Other , Electromagnetic Relays

Monitoring Relays D1 VCR1

Monitoring Relays D1 VCR1

Price 2595 INR / Piece

Minimum Order Quantity : 10 Pieces

Power Consumption : <2 VA

Contact Form : 1 Changeover (SPDT)

Dielectiric Strength : 2 kV AC for 1 minute

Theory : Other , Electromechanical Relay

Phase Failure Relays ALV D2

Phase Failure Relays ALV D2

Price 1200 INR / Piece

Minimum Order Quantity : 10 Pieces

Power Consumption : <3VA

Contact Form : 1 C/O (SPDT)

Dielectiric Strength : 2kV AC for 1 min

Theory : Other , Electromagnetic relay

Phase Failure Relays S2 VMR3

Phase Failure Relays S2 VMR3

Price 1400 INR / Piece

Minimum Order Quantity : 10 Pieces

Power Consumption : 3VA

Contact Form : SPDT (Single Pole Double Throw)

Dielectiric Strength : 2kV AC for 1 min Between Coil and Contacts

Theory : Other , Electromechanical Relay



Back to top